ENVIRONMENTAL CONDITIONS: ● Cooling: Nature convection with U bracket heatsink ● Operating Temperature: 0°C~+70°C ● Operating Humidity: 20%~85% RH. (Non condensing) ● Storage Temperature: -20°C~+80°C ● Storage Humidity: 10%~90% RH. (Non condensing) ● Operating Altitude: 10M Below Sea level to 3000M Above Sea level DC INPUT CHARACTERISTICS: ● Input connector type: 30A/300V UL Approved 3-Pin Terminal ● Input Current: 18A/15A/13A/10A(max.) @Full Load & Low Line ● Inrush Current: Less than 10A Cold start @25°C ambient
OVERALL PERFORMANCE: ● Efficiency: 80% typical @12V DC Full Load, 24V DC Full Load, 48V DC Full Load ● Efficiency: 85% typical @120V DC Full Load ● Hold up time: ● Rise time: 16ms ● Power Good Signal: ● Short Circuit Protection (SCP): All output with SCP (shutdown and latch off) ● Over Power Protection (OPP): Peak power protected to 130%±10% of continuous rated power (shutdn and latch off) ● Over Voltage Protection (OVP): +12V, +24V, 48V, 120V DC & 25°C each unit output voltage
RELIABILITY: ● MTBF (Mean Time Between Failure): >50,000 hours @max. Load, 12V, 24V, 48V DC & 25°C ambient ● Safety Standards: Meet UL60950, TüV EN60950 ● Safety Approved: ● EMI Compatibility (EMC) Standard: FCC Part 15 Class B, CISPR22 (EN55022) Class B (CE mark) ● Dielectric Withstand Input to Output: 1500Vac for 1second ● Dielectric Withstand Input to Frame Ground: 1500Vac for 1second ● Leakage Current: <0.75mA @250Vac
Input & Output Device Connector Specific: ● Connector type: 25A/300V UL Approved 8-Pin Terminal Power Chassis Dimension: ● 172(L) x 98(w) x 40(H)mm