| For Server and workstation |
| Conformed to IPC |
1U Type |
| Output Capacity: |
200Watts Continuous |
| Provide Single |
+12V rails, output current is 14A |
| Ripple & Noise |
Low |
| Operation Temperature: |
0~50°C |
| Low-Noise Fan |
40mm |
| Active |
PFC |
| Dimension: |
180 x 100 x 40.5mm |
| Life expectancy: |
MTBF >100,000 hours |
| Multiple Protections Function: |
(OCP, OVP, UVP, OPP) |
| Safety Approvals: |
CE, TUV, CB, UL, CCC and BSMI |
VOLTAGE |
OUTPUT CURRENT |
REGULATION |
| MIN(A) |
MAX(A) |
LOAD |
LINE |
|
+5V |
1 |
18 |
±5% |
±1% |
|
+3.3V |
1 |
17 |
±5% |
±1% |
|
+12V |
1 |
14 |
±5% |
±1% |
|
-12V |
0 |
0.5 |
±10% |
±1% |
|
+5VSB |
0 |
2 |
±5% |
±1% |
|